DuraVent PelletVent for Multi-Fuel 3″ x 6″ Black Straight Pipe Length Fashion

$34.27

SKU: US-7913252389034 Category:
Description

Description

DuraVent PelletVent for Multi-Fuel 3″ x 6″ Black Straight Pipe Length

Patent-pending venting system designed for stoves that burn multi-fuels or oil fuel. Multi-fuels include: wood pellets, corn, cherry pits, switch grass, coffee husks, walnut shells, soybeans, wheat, sunflower hulls, rapeseed, and sugar beets. (Rated for continuous use flue temperatures up to 570° F.) All PelletVent components that come into contact with flue gases are built with an inner wall of corrosion resistant super-ferritic metal.

PelletVent is uncompromised in attention to detail and performance. Select components are available in black to enhance interior aesthetics. Seams are factory-sealed on all elbows, tees, and fittings. Available in 3” and 4” sizes through hardware and home centers. 

What’s Included

  • Pipe Length

Features

  • Features fully unitized, twist-lock construction in 3” and 4” diameters.
  • Listed at 1” clearance to combustibles.
  • It can be used in both vertical and horizontal installations.
  • Stainless steel wall combined with a galvanized outer wall.
  • Pipe OD is diameter plus 5⁄8”.
  • Galvalume or painted black outer finish.

Specifications

Brand DuraVent
Series PelletVent for Multi-Fuel
Model 3PVL-06B
Product Type Pipe Length
Finish Black
Size (Diameter) 3″
Length 6″

Technical Specifications

Warranty

DuraVent, Inc. (“DuraVent”) provides this limited lifetime warranty for all of its products with the exception of Ventinox® (lifetime), and PolyPro® (ten years). Subject to the limitations set forth below, DuraVent warrants that its products will be free from defects in material or manufacturing, if properly installed, maintained, and used.
Click to See Warranty Coverage and Limitations

DuraVent, Inc. (“DuraVent”) provides this limited lifetime warranty for all of its products with the exception of Ventinox® (lifetime), and PolyPro® (ten years). Subject to the limitations set forth below, DuraVent warrants that its products will be free from defects in material or manufacturing, if properly installed, maintained and used. DuraVent products are fully warranted if installed only by a professional installer. This Warranty is transferable from the original homeowner to the buyer of the home. This warranty does not cover normal wear and tear, smoke damage or damage caused by chimney fires, acts of God, or any product that was: (1) purchased other than from an authorized DuraVent dealer, retailer or distributor; (2) modified or altered; (3) improperly serviced, inspected or cleaned; or (4) subject to negligence or any use not in accordance with the installation instructions included with the product as determined by DuraVent.

 

DuraVent provides the following warranties for its products: One Hundred Percent (100%) MSRP 15 years from the date of purchase, and Fifty Percent (50%) thereafter, except for the following limitations on: all Termination Caps and DuraBlack® are warranted at One Hundred Percent (100%) for five years. All warranty obligations of DuraVent shall be limited to repair or replacement of the defective product pursuant to the terms and conditions applicable to each product line. These remedies shall constitute DuraVent’s sole obligation and sole remedy under this warranty. This warranty provides no cash surrender value. The terms and conditions of this warranty may not be modified, altered or waived by any action, inaction or representation, whether oral or in writing, except upon the express, written authority of an executive officer of DuraVent.

 

Corn, bio-fuels, driftwood or other wood containing salt, preservative-treated lumber, plastic and household trash or garbage, or wood pellets containing such materials must not be burned in the appliance or fireplace. In case of a chimney fire, the chimney must be inspected and approved by a certified Chimney Sweep before reuse. After each annual inspection, maintenance, and cleaning, the certified Chimney Sweep must fill out and date the appropriate section of the warranty card provided with the chimney liner.

 

LIMITATIONS ON INTERNET SALES: Notwithstanding any other terms or conditions of this Limited Lifetime Warranty, DuraVent provides no warranty for the following specific products if such products are not installed by a qualified professional installer: DuraTech®, DuraTech® DTC, DuraTech® Premium, DuraPlus HTC®, DDW®, DuraChimney® II, PelletVent Pro®, DirectVent Pro®, FasNSeal®, FasNSeal® W2, FasNSeal® Flex, and PolyPro®, and DuraVent’s relining products including DuraLiner®, DuraFlex® (SW, Pro, 316, 304), and Ventinox®. For purposes of this warranty, a trained professional installer is defined as one of the following: licensed contractors with prior chimney installation experience, CSIA Certified Chimney Sweeps, NFI Certified Specialists, or WETT Certified Professionals.

 

DuraVent must be notified and given the opportunity to inspect defective product prior to replacement under the terms of this limited lifetime warranty. All warranty claims must be submitted with proof of purchase. Labor and installation costs are not covered under this warranty. To obtain warranty service contact: DuraVent Warranty Service, 877 Cotting Ct., Vacaville CA 95688, or call 800-835-4429.

 

WHERE LAWFUL, DURAVENT DISCLAIMS ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL DURAVENT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR SPECIAL DAMAGES OR DIRECT OR INDIRECT LOSS OF ANY KIND, INCLUDING BUT NOT LIMITED TO PROPERTY DAMAGE AND PERSONAL INJURY. DURAVENT’S ENTIRE LIABILITY IS LIMITED TO THE PURCHASE PRICE OF THIS PRODUCT. SOME STATES DO NOT ALLOW LIMITATIONS ON IMPLIED WARRANTIES, OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.

 

Download DuraVent Limited Lifetime Warranty here.

Documents & Files

  • PelletVent for Multi-Fuel Catalog
  • PelletVent for Multi-Fuel Product Brochure
  • PelletVent for Multi-Fuel Installation Instructions

Frequently Asked Questions

What are PelletVent for Multi-Fuel’s Specifications?

Patent-pending venting system designed for stoves that burn multi-fuels or oil fuel. Multi-fuels include: wood pellets, corn, cherry pits, switch grass, coffee husks, walnut shells, soybeans, wheat, sunflower hulls, rapeseed, and sugar beets. (Rated for continuous use flue temperatures up to 570° F.) All PelletVent components that come into contact with flue gases are built with an inner wall of corrosion resistant super-ferritic metal.

PelletVent is uncompromised in attention to detail and performance. Select components are available in black to enhance interior aesthetics. Seams are factory-sealed on all elbows, tees, and fittings. Available in 3” and 4” sizes through hardware and home centers. 

 

Materials and Construction

PelletVent for multi-fuel is a double-wall pipe with an inner wall of corrosion resistant stainless steel and a galvalume outer wall. Painted black for exterior available.

 

Clearances

1″ clearance to combustibles in the USA and Canada for appliances using multi-fuels or oil.

 

Diameters

3″ and 4″

 

Listings

c-UL-us Listed to UL 641 (MH8381 and MH14420). ULC Listed to ULC S609, ULC/ORD C441 (CMH1439 and CMH1440).

What is PelletVent for Multi-Fuel’s Typical Installation?


Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation.

  • The inner pipe diameter should match the outlet size of the appliance. For installations that require 4″ vent and the appliance has a 3″ outlet, use an Increaser Adapter 3″-4″.
  • Check the appliance manufacturer’s installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). Also, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc.
  • Be fire safe! Maintain the minimum clearances (air-space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer’s installation instructions. Use proper support and bracing. Follow local building codes and have your venting system inspected.

 

More Typical Installations

1   Vertical Cap
2   Storm Collar
3   Flashing
4   Cathedral Ceiling Support Box
5   Pipe
6   45° Elbow
7   Appliance Adapter
8   60° Flexible Length
9   90° Elbow
10  Horizontal Cap
11  Wall Thimble
12  Celling Support Firestop Spacer
13  Tee w/Clean-Out Tee Cap
14  Tee Support Bracket

 

Planning Your Installation:

1.  Refer to the Typical PelletVent Pro Installations diagram, on the opposite page, to be familiar with some of the standard PelletVent Pro installations and the required component parts.
2.  For a horizontal termination, you will need a Wall Thimble and a Horizontal Cap. The cap must be installed with a 6″ clearance to the outside wall (refer to appliance manufacturer’s installation instructions for other clearances).
3.  For a vertical termination, you will need a Cathedral Ceiling Support Box or Flat Ceiling Support, Attic Insulation Shield (if passing through an attic), Flashing, Storm Collar, and Vertical Cap.
4.  Determine the length of PelletVent Pro pipe required. For a vertical termination, measure the pitch of the roof and select the proper flashing. The required minimum height above the roof is 12″.
5.  Pellet stove inserts in masonry fireplaces will require a flex pipe to snake the vent past the smoke shelf. For transition from PelletVent to an existing DuraPlus Chimney, a Chimney Adapter is available.
6.  For vertical rise of PelletVent Pro on the outside of the house, Wall Straps should be used at 4′ intervals to provide proper support.
7.  Important! Check to be sure that the appliance and the venting system are in compliance with all minimum clearance to combustible requirements.

 

The following design recommendations are a general guideline to assist in the design and selection of venting components for your installation. Always follow DuraVent Installation instructions before installing your chimney system (found with the cap or support box).

  • Size the vent to meet the appliance manufacturer’s specifications.
  • Avoid long runs and excessive use of elbows. Refer to the appliance manufacturer for minimum rise and maximum run configurations for the venting system.
  • Use an Appliance Adapter to ensure a proper connection to appliance. Seal adapter to appliance with high temperature sealant.
  • Use a Single Tee with Clean-Out Tee Cap to facilitate easy cleaning. It is recommended to use a tee off the back of an appliance.
  • In the United States and Canada, maintain the minimum 1″ clearance (air space) from vent pipe to combustibles. Use proper support and bracing. Follow local building codes and have your venting system inspected. Be fire safe!

What are the DuraVent Product Lines?


DuraVent offers the following product lines:

DuraTech 5″-8″: All-fuel, double-wall chimney system. UL 103 HT and ULC S604.

DuraTech 10″-24″: All-fuel, double-wall chimney system. UL 103.

DuraTech Canada is a double-wall, all-fuel chimney system for use with wood stoves, wood fireplaces, and other appliances using wood, oil, gas, or coal.

DuraPlus: Triple-wall all-fuel chimney with two layers of insulation.

DuraPlus HTC: Double-wall all-fuel chimney built to Canadian standards.

DuraChimney II: Double-wall air-cooled chimney for pre-fabricated masonry chimneys.

Combustion Air Systems: DuraVent’s exclusive, patent-pending system is designed to bring in outside combustion air directly to your wood or pellet stoves.

DuraBlack: Single-wall stovepipe.

DVL: Double-wall stovepipe.

DuraLiner: Double-wall factory insulated masonry relining system.

DuraFlex: Flexible stainless steel liners.

DuraFlex Aluminum: Flexible aluminum relining for masonry chimney. UL 1777 and ULC S635.

Ventinox: Flexible stainless steel liner.

CVS: Provides Ortal Branded Fireplace Systems and as a Direct Vent for Pellet Stoves.

PelletVent: Multi-fuel vent.

PelletVent Pro: Vents appliances using oil, wood pellets, corn, and other biofuels.

DirectVent Pro: Unitized, co-axial venting system for direct vent gas or propane stoves, heaters, and fireplaces.

Type B Gas Vent: Vents natural gas, liquid propane category I, and draft-hood equipped appliances

FasNSeal: Single, double-wall, flex, and concentric venting for category II, III, and IV appliances.

FasNSeal 80/90: Combined Category I and IV venting for Gas-Burning Appliances.

PolyPro: Single-wall, flex, and concentric venting made of polypropylene for category II and IV condensing appliances that operate up to 248 degrees.

PolyPro Flex: PolyPro double-wall flex lining system. Environmentally safe venting system for high-efficiency appliances, including water heaters, condensing boilers, and warm air furnaces. ULC S636.

DuraSeal: Single-Wall and Double-Wall Special Gas Vent Boiler Adapters.

DuraStack: A modular double-wall, positive pressure chimney for use with boiler breeching and stack, engine exhaust, and grease duct (DIS only)

DuraStack Pro: Models DIS and DAS. Modular Double-Wall Positive Pressure Chimney for Boiler Breeching, Stack, and Engine Exhaust.

Shipping & Delivery

We accept returns on non-sale items that are in original packaging, unused, and unwashed within 30 days of receipt. Please follow our returns/exchanges process below. If items do not meet our requirements for return, they will be shipped back to you in lieu of a refund. Shipping and handling charges are non-refundable (exceptions may apply).

Returns & Exchanges Process: If item(s) fit within our returns guidelines found in the Returns. Please allow 7-10 business days for the credit to appear on your account after your return is processed.