DuraVent DuraTech 6″ Diameter Galvalume Steel 36″ Pipe Length All Fuel Chimney Pipe Online

$119.40

Clear
SKU: US-4846721925198 Category:
Description

Description

DuraVent DuraTech 6″ Diameter Galvalume Steel 36″ Pipe Length All Fuel Chimney Pipe

All-fuel, double-wall chimney system. UL 103 HT and ULC S604

With a Thermal Tech blanket insulation encased between dual walls, DuraTech offers optimum safety and performance. It keeps the outer wall of the chimney cool while ensuring high flue gas temperatures for optimum draft performance.

The inner wall is 25% thicker than competitive chimneys for an extra margin of safety. No locking bands or mechanical fasteners are required.

DuraTech’s sleek 1″ wall design provides for easy installations through 16″ on-center framing. For tight installations, a Reduced Clearance Square Ceiling Support Box is available (6″ diameter DuraTech only).

Designed for normal, continuous operation at 1000°F flue gas temperatures, DuraTech is subjected to rigorous and stringent high-temperature requirements of the UL standard, including one hour at 1400°F, plus three ten-minute chimney fire test at 2100°F.

Product Details

Model DuraTech 6″
Part no. 6DT-36
Part no. 6DT-36CF
Inner Diameter, A 6 inch
Outer Diameter, B 8 inch
Pipe Length 36 inch
Inner Wall Material 0.020” 430 Stainless Steel
Outer Wall Material 0.021” Galvalume Steel

 

(CF) The designation indicates additional protective carton foam for shipping.

Chimney Pipe Dimension

 

To calculate installed length of 5”, 6”, 7”, or 8” DuraTech Chimney, subtract 1 1⁄4” from each joint overlap of chimney pipe. Allow a minimum of 2” air space to
combustibles when installing DuraTech Chimney.

Specifications

Applications

DuraTech is a double-wall, all-fuel chimney system for use with wood stoves, fireplaces, furnaces, boilers, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas, and zero-clearance fireplaces that are factory-built.

Materials and Construction

5”, 6″ 7″, or 8” diameter pipe features an inner wall of .020” 430 stainless steel. Outer wall options of .016” 430 stainless steel or .021” galvalume steel. Refractory insulation is encased between walls. Stainless steel end rings seal the pipe.

DuraTech features lightweight insulation, twist-lock fittings, support boxes with factory-installed starter sections, elbows with 360° swivel base, select black finish pipe lengths, five-foot length pipe sections, and adjustable pipe lengths.

Clearances

2” clearance to combustibles.

Shrouds

Shroud specs allow the installer to create a UL-listed shroud to hide the termination at the top of the chase for the safest installation.

Product Features

  • A wide variety of diameters is available.
  • Most lengths are available.
  • Twist-lock fittings. No locking bands or mechanical fasteners are required.
  • Made by the industry leader with over 50 years of manufacturing.
  • The swivel base allows an installer to line up the elbow without unlocking and repositioning the elbow, saving time and money.
  • Ensures that the installer gets both the offset and return elbow along with an elbow support bracket to make a properly code-approved offset.
  • Limited Lifetime Warranty The best Warranty in the industry. 15 years 100%, 15 years, and up 50%. Gives the installer and homeowner the greatest peace of mind in a quality installation.

Typical Chimney Installation

Refer to our Typical Installation to select the appropriate component parts for your installation.

  •  DVL/DuraBlack Chimney Adapter must be used when connecting DVL pipe to a Ceiling Support Box or Finishing Collar. When connecting the DuraBlack pipe, a DVL/DuraBlack Chimney Adapter, DuraBlack Slip Connector, or Snap-Lock Adapter must be used.
  • Wall Thimble must be installed with an appropriate length of chimney pipe for all horizontal through-the-wall installations. To accommodate thicker walls, the telescoping pieces of the Wall Thimble can be separated, and a field-fabricated extension may be installed.
  • Attic Insulation Shield must be used in all installations that pass through an attic, regardless of whether the attic is insulated or not.
  • Firestop Radiation Shield must be used when a chimney passes through a floor or ceiling without a support box.

 

Downloads

  • Typical Chimney Installations
  • Product Catalog
  • Product Installation Instructions
Additional information

Additional information

Material

36" pipe length 6DT-36, 36" pipe length 6DT-36CF (w/ carton filler)

Shipping & Delivery

We accept returns on non-sale items that are in original packaging, unused, and unwashed within 30 days of receipt. Please follow our returns/exchanges process below. If items do not meet our requirements for return, they will be shipped back to you in lieu of a refund. Shipping and handling charges are non-refundable (exceptions may apply).

Returns & Exchanges Process: If item(s) fit within our returns guidelines found in the Returns. Please allow 7-10 business days for the credit to appear on your account after your return is processed.